Head-Worn Condenser Microphone, Cardioid Pattern, Two-Ear Headband, 100 Hz to 15 kHz, 20 mV/Pa, 135 dB Max SPL, Sweat Resistant, 2 to 10 V Bodypack Powering, Micro-Coaxial Screw Termination
The AKG HC644 MD is a back-electret condenser head-worn microphone with a cardioid polar pattern, a 100 Hz to 15,000 Hz response within plus or minus 3 dB and a sensitivity of 20 mV/Pa measured at 9 V into 18 kilohms. It is the newer generation developed from the established C544 and C555 head-worn line, aimed at corporate and education presenters but built with fitness instruction squarely in mind. Maximum SPL is 135 dB at 1 percent distortion, the signal-to-noise ratio is 60 dB-A and the equivalent noise level is 34 dB-A, with a 200 ohm source impedance into a 2,000 ohm recommended load. Every design choice in it favours staying put over disappearing.
Headband architecture is the first thing that separates this microphone from an ear-hook, because the frame wraps behind the head and bears against both ears rather than hanging from one. A single hook relies on the shape of one ear to resist every force applied to the boom, so a jump landing, a floor roll or a fast head turn can rotate the whole assembly and change the capsule position mid-sentence, while a two-point frame constrains rotation in every axis at once. Spin instructors, aerobics teachers and dance leaders are the wearers who need that, since their movement is continuous and unpredictable and there is no operator available to reset a slipped boom. The cost is a headband that is more visible from a side camera angle and less compatible with an elaborate hairstyle, which is exactly why the single-ear models in this catalogue still exist for presentation work.
Pattern is cardioid, and in a fitness or teaching room that directionality is doing hard work. A cardioid capsule attenuates sound arriving from the sides and rear, so the wall-mounted or ceiling-hung loudspeakers reinforcing an instructor's voice are partially rejected by the very microphone feeding them, and that rejection is what determines how loud the system can go before it rings. Instructors work in rooms designed for music playback at high level, with speakers often only a few feet from where they stand, which is the single hardest feedback environment in installed audio. Uniform pattern behaviour is what the factory emphasises, because a pattern that holds its shape across the band rejects across the band rather than leaking at one frequency where feedback will then appear.
Response runs 100 Hz to 15,000 Hz within plus or minus 3 dB, which is narrower than the full-range miniature microphones elsewhere in this catalogue and is deliberate rather than a limitation. Rolling off below 100 Hz removes the energy that does nothing useful for speech intelligibility but does plenty of damage, namely footfall through the floor into the headband, low-frequency handling noise from a boom being touched, and the proximity-effect bass build-up that any close-mounted capsule generates. Cutting the top at 15 kHz similarly trims sibilance and air-conditioning hiss that would otherwise be amplified into a hard room. An instructor shouting counts over a driving music bed gets a cleaner, more present voice from this curve than a full-range capsule would deliver in the same room, and the sound system has less to fight.
Operating voltage is 9 V nominal with a working range of 2 to 10 V, and current consumption is 500 microamperes or less, which means the microphone is compatible with a wide spread of bodypack transmitters and takes almost nothing from the transmitter battery. Sensitivity of 20 mV/Pa is high in absolute terms, and a high-output capsule matters on a bodypack because it lets the transmitter's input gain stay low, keeping the transmitter's own preamplifier noise well below the programme. High RF rejection is specified alongside that, addressing the interference that a head-worn cable picks up in rooms full of wireless microphones and wireless networking traffic. Termination is a two-pin micro-coaxial screw connector with the MDA1 adapter connector supplied, so the transmitter-specific plug is a changeable part rather than a permanent one.
Sweat-resistant construction and an operating range of -4 to 140 F (-20 to 60 C) define the working envelope, and the microphone ships with the MDA1 adapter, a foam windscreen, a carrying case and a quick start guide. Perspiration is conductive and salt-laden and it reaches a boom-mounted element within minutes of a class starting, so moisture resistance here is a durability specification rather than a marketing line, and the wide temperature range covers both a hot studio and outdoor drill work. Gyms and studio chains, university lecture theatres, corporate presenters who need both hands free, sports coaches and trade-show demonstrators working eight-hour shifts are the buyers who land on this microphone. Including a hard carrying case is a small detail that matters more than it sounds, because a headband that lives in a gym bag is the one that gets bent.
| MPN | 2793H00100 |
|---|---|
| Color | Black |
| Element | Condenser |
| Pattern | Cardioid |
| Power Source | Plug-In Power |
| Form | Headworn Microphone |
| Output | Micro-Coaxial Screw |
| Channels | Mono |
| UPC / EAN | 885038039044 |
| Brand | AKG |
| Product Condition | New |
| Availability | Out of Stock |
| Microphone Type | Back electret condenser |
| Form Factor | Head-worn, two-ear headband with fixed boom |
| Polar Pattern | Cardioid |
| Frequency Range | 100 Hz to 15,000 Hz, plus or minus 3 dB |
| Sensitivity | 20 mV/Pa at 9 V into 18 kilohms |
| Maximum SPL at 1 Percent THD | 135 dB |
| Signal-to-Noise Ratio | 60 dB-A |
| Equivalent Noise Level | 34 dB-A |
| Electrical Impedance | 200 ohms |
| Recommended Load Impedance | 2,000 ohms |
| Operating Voltage | 9 V nominal, 2 to 10 V range |
| Current Consumption | 500 microamperes or less |
| Termination | Two-pin micro-coaxial screw connector |
| Included Adapter | MDA1 adapter connector for the bodypack transmitter interface |
| Moisture Resistance | Sweat-resistant construction |
| Operating Temperature | -4 to 140 F (-20 to 60 C) |